GENERAL DESCRIPTION
STARTING/CHARGING SYSTEMS
1. General Description
A: SPECIFICATIONS
1. NON-TURBO MODEL
Item
Type
Vehicle type
Model
Starter
Designation
Reduction type
MT vehicles
AT vehicles
MOOOT83981
MOOIT86481
Generator
Manufacturer
Mitsubishi Electric
Voltaae and outDut
12 V
-
1
.O
kW
12
V
-
1.4 kW
I
Rotating speed
I
920 rpm or more
I
740 rDm or more
1
-
Direction of rotation
Number of pinion teeth
Voltage
No-load charac-
teristics
Current
Rotating speed
Current
Load character-
istics
Torque
Voltage
I
-
Counterclockwise (when observed from pinion)
8
9
11
v
90 A or less
7.5
v
7.7
v
300 A
400 A
16.0 N.m (1.63 kg-m, 11.8 ft-lb) or
more
2,800 rpm or more
2,400 rpm or more
8.6 N.m (0.88 kg-m, 6.3 ft-lb) or more
Lock character-
istics
sc-2
Voltage
4 v
3.5
v
Current
650 A or less
940 A or less
Torque
14.7 N.m (1.50 kgf-m, 10.8 ft-lb) or
28.9 N.m (2.95 kgf-m, 21.3ft-lb) or
more
more
Type
Model
Manufacturer
Polarity on ground side
Rotating direction
Voltage and output
Rotating-field three-phase type, Voltage regulator built-in type, with load
response control system
A2TB6291
Mitsubishi Electric
Negative
Clockwise (when observed from Dullev side)
12 V
-
90 A
Armature connection
Output current
Regulated voltage
3-phase Y-type
1,500 rpm
-
36 A or more
2,500 rpm
-
65 A or more
5,000 rpm - 86 A or more
14.1
-
14.8 V [20°C (68"F)I

Hide quick links: