Table 1 Fax Diagnostic signal numbers
Signal No. Output
150
V.34 Signal Output
151
V.34 Signal Output
152
V.34 Signal Output
153
V.34 Signal Output
154
V.34 Signal Output
160
DTMF Signal Output
161
DTMF Signal Output
162
DTMF Signal Output
163
DTMF Signal Output
164
DTMF Signal Output
165
DTMF Signal Output
166
DTMF Signal Output
167
DTMF Signal Output
General Procedures and Information
GP 5, GP 6
Description
24000/3429 (HDLC Flag)
26400/3429 (HDLC Flag)
28800/3429 (HDLC Flag)
31200/3429 (HDLC Flag)
33600/3429 (HDLC Flag)
Signal Tone 697Hz
Signal Tone 770Hz
Signal Tone 852Hz
Signal Tone 941Hz
Signal Tone 1209Hz
Signal Tone 1336Hz
Signal Tone 1477Hz
Signal Tone 1633Hz
GP 6 Resetting the Administrator Password
Purpose
The purpose of this procedure is to allow the CSE to recover the Administrator Password in sit-
uations where the customer has changed the password from the default value, and subse-
quently lost or forgotten the password.
Procedure
1.
Enter
UI Diagnostic
Mode.
2.
Press the Access button on the Control Panel
3.
On the display, select System Settings, then Common Settings, then Diagnostics.
4.
Select NVM Read/Write.
5.
Enter location 700-171 and press Confirm/Change. This is the current password. You
can provide this number to the customer, or set the location to the default value (11111)
and allow the customer to enter a new number from Tools mode.
09/03
6-128
Initial issue
DC 3535/2240/1632, WC M24