13.3 Monitor Display (Un) Operations on the Panel Operator
13.3.4 Safety Input Signal Monitor (Un015)
• If the output signal that corresponds to the display digit number is ON, the bottom LED seg-
ment will be lit.
The allocations are given in the following table.
Display Digit
Number
Information
Display Examples
A display example for output signals is shown below.
• When the ALM (Servo Alarm) Signal Is OFF
8
13.3.4 Safety Input Signal Monitor (Un015)
Interpreting the Display
You can display the status of allocated signals on the LED segments of the Panel Operator.
LED Segments
8
7
• If the signal that corresponds to the display digit number is ON, the top LED segment will be
lit.
• If the signal that corresponds to the display digit number is OFF, the bottom LED segment will
be lit.
The allocations are given in the following table.
Display Digit
Number
13-10
Output Pin Numbers
1
CN1-31and CN1-32
2
CN1-25 and CN1-26 /SO1+ (/COIN+ or /V-CMP+) and /SO1- (/COIN- or /V-CMP-)
3
CN1-27 and CN1-28 /SO2+ (/TGON+) /SO2- (/TGON-)
4
CN1-29 and CN1-30 /SO3+ (/S-RDY+) /SO3- (/S-RDY-)
5
CN1-37
6
CN1-38
7
CN1-39
8
–
The configuration of the output circuits is shown below.
OFF: Transistor OFF
ON: Transistor ON
Example:
SERVOPACK
ON (transistor ON)
The top segment of digit 1 is lit.
7
6 5 4 3 2 1
Top: ON
Bottom: OFF
Display digit number
6
5
4 3 2 1
Input Pin Numbers
1
CN8-3 and CN8-4
2
CN8-5 and CN8-6
3
–
4
–
5
–
6
–
7
–
8
–
Signal Name (Default Setting)
ALM+, CALM-
ALO1
ALO2
ALO3
Reserved.
Signal
/HWBB1
/HWBB2
Reserved.
Reserved.
Reserved.
Reserved.
Reserved.
Reserved.