6.6 Position Control

6.6.7 Reference Pulse Inhibition Function

6.6.7

Reference Pulse Inhibition Function

You can stop the SERVOPACK from counting the reference input pulses during position con-
trol. When this function is enabled, the SERVOPACK will ignore the reference pulse input.
/INHIBIT (Reference Pulse Inhibit) Signal
If you set the control method to switch between normal position control and position control
with reference pulse inhibition (Pn000 = n.B), the /INHIBIT signal is used as the Refer-
ence Pulse Inhibit signal (default setting).
 When Using the Default Input Signal Allocations (Pn50A = n.0)
Type
Input
 When Changing Input Signal Allocations (Pn50A = n.1)
If you set Pn000 = n.X (Control Method Selection) to 1, 5, 7, or 8, the /INHIBIT signal is
used as the Reference Pulse Inhibit signal for reference pulse inhibition.
Type
Input
Note: You must allocate the /INHIBIT signal to use it. Use Pn50D = n.X (/INHIBIT (Reference Pulse Inhibit
Input) Signal Allocation) to allocate the signal to a connector pin. Refer to the following section for details.
 Reference Pulse Inhibition Settings
To use reference pulse inhibition, set Pn000 = n.X (Control Method Selection) to 1, 5, 7 or
8.
Parameter
Pn000
Information
6-38
Signal
Connector Pin No.
CN1-41
/INHIBIT
(default setting)
Signal
Connector Pin No.
/INHIBIT
Must be allocated.
6.1.2 Output Signal Allocations on page 6-7
Control Method

n.
1
Position control
Switching between internal set

n.
5
speed control and position control
Switching between position control

n.
7
and speed control
Switching between position control

n.
8
and torque control
Switching between normal position

n.
B
control and position control with
reference pulse inhibition
Counting reference pulses can be inhibited only for position control.
Signal Status
ON (closed)
Counting the reference pulses is stopped.
OFF (open)
The reference pulses are counted.
Signal Status
ON (closed)
Counting the reference pulses is stopped.
OFF (open)
The reference pulses are counted.
Used Input Sig-
/INHIBIT
/INHIBIT
/SPD-A
/SPD-B
/SPD-D
/C-SEL
/INHIBIT
/C-SEL
/INHIBIT
/C-SEL
/INHIBIT
Meaning
Meaning
When
nals
Enabled
After restart
Classifica-
tion
Setup