5.12 Overtravel and Related Settings

5.12.3 Motor Stopping Method for Overtravel

5.12.3 Motor Stopping Method for Overtravel

You can set the stopping method of the Servomotor when overtravel occurs in Pn001 =
n.XX (Motor Stopping Method for Servo OFF and Group 1 Alarms and Overtravel Stopping
Method).
Pn001
*
You cannot decelerate a Servomotor to a stop during torque control. For torque control, the Servomotor will be
stopped with the dynamic braking or coast to a stop (according to the setting of Pn001 = n.X (Motor Stop-
ping Method for Servo OFF and Group 1 Alarms)), and then the Servomotor will enter a coasting state.
Refer to the following section for information on stopping methods other than those for over-
travel.
5.14.1 Stopping Method for Servo OFF on page 5-43
Stopping the Servomotor by Setting Emergency Stop
Torque
To stop the Servomotor by setting emergency stop torque, set Pn406 (Emergency Stop
Torque).
If Pn001 = n.X is set to 1 or 2, the Servomotor will be decelerated to a stop using the
torque set in Pn406 as the maximum torque.
The default setting is 800%. This setting is large enough to allow you to operate the Servomo-
tor at the maximum torque. However, the maximum emergency stop torque that you can actu-
ally use is the maximum torque of the Servomotor.
Pn406
*
Set a percentage of the motor rated torque.
Stopping the Servomotor by Setting the Deceleration Time
To specify the Servomotor deceleration time and use it to stop the Servomotor, set Pn30A
(Deceleration Time for Servo OFF and Forced Stops).
Pn30A
If you set Pn30A to 0, the Servomotor will be stopped with a zero speed.
The deceleration time that you set in Pn30A is the time to decelerate the motor from the maxi-
mum motor speed.
5-34
Motor Stopping
Parameter
Method

n.
00
(default setting)
Dynamic brake

n.
01

n.
02
Coasting

n.
1
Deceleration
according to

n.
2
setting of Pn406

n.
3
Deceleration
according to

n.
4
setting of Pn30A
Emergency Stop Torque
Setting Range
Setting Unit
0 to 800
Deceleration Time for Servo OFF and Forced Stops
Setting Range
Setting Unit
0 to 10,000
Status after
*
Stopping
Coasting
Zero clamp
Coasting
Zero clamp
Coasting
Default Setting
*
800
1%
Default Setting
1 ms
0
When Enabled
Classification
After restart
Setup
Speed
Position
When Enabled
Classification
Immediately
Speed
Position
When Enabled
Classification
Immediately
Torque
Setup
Setup

Advertisement

Table of Contents
loading

Table of Contents