6.16.2

Manual Adjustment

You can use this function if you automatically adjust the motor current detection signal offset
and the torque ripple is still too large.
If the offset is incorrectly adjusted with this function, the Servomotor characteristics may be
adversely affected.
Observe the following precautions when you manually adjust the offset.
Important
• Operate the Servomotor at a speed of approximately 100 min
• Adjust the offset while monitoring the torque reference with the analog monitor until the ripple is
minimized.
• Adjust the offsets for the phase-U current and phase-V current of the Servomotor so that they
are balanced. Alternately adjust both offsets several times.
The offset does not use a parameter, so it will not change even if the parameter settings are
Information
initialized.
Preparations
Always check the following before you manually adjust the motor current detection signal off-
set.
• The parameters must not be write prohibited.
Applicable Tools
The following table lists the tools that you can use to manually adjust the offset and the applica-
ble tool functions.
Tool
Panel Operator
Digital Operator
SigmaWin+
Operating Procedure
Use the following procedure to manually adjust the motor current detection signal offset.
1.
Operate the motor at approximately 100 min
2.
Click the
3.
Select Adjust the Motor Current Detection Signal Offsets in the Menu Dialog Box.
The Adjust the Motor Current Detection Signal Offsets Dialog Box will be displayed.
4.
Click the Continue Button.
Function
Fn00F
Fn00F
Setup - Adjust Offset -
Adjust the Motor Current
Detection Signal Offsets
Servo Drive Button in the workspace of the Main Window of the SigmaWin+.
6.16 Adjusting the Motor Current Detection Signal Offset
-1
.
Operating Procedure Reference
13.4.14 Manually Adjust Motor Current Detection Sig-
nal Offset (Fn00F) on page 13-22
Σ-7-Series Digital Operator Operating Manual (Man-
ual No.: SIEP S800001 33)
Operating Procedure on page 6-103