13.4 Utility Function (Fn) Operations on the Panel Operator

13.4.18 Multiturn Limit Setting after Multiturn Limit Disagreement Alarm (Fn013)

Step
4
5
13.4.18 Multiturn Limit Setting after Multiturn Limit Disagree-
ment Alarm (Fn013)
Refer to the following section for information on this utility function other than the procedure.
6.12.9 Multiturn Limit Disagreement Alarm (A.CC0) on page 6-83
Step
1
2
3
4
5
6
7
13-26
Panel Display after
Operation
MODE/SET
MODE/SET
Panel Display after
Operation
MODE/SET
MODE/SET
MODE/SET
MODE/SET
MODE/SET
To enable the change to the settings, turn the power supply to the SERVOPACK OFF and ON again.
Keys
Press the MODE/SET Key. The software version of
the encoder will be displayed.
Additional Information
If you press the MODE/SET Key again, a pre-pro-
DATA/
grammed display will appear. The display will change
as follows: 0.0000 → S.FFFF → F.FFFF.
Press the DATA/SHIFT Key for approximately one
second to return the display to Fn012.
DATA/
Keys
Press the MODE/SET Key to enter Utility Function
Mode.
DATA/
Press the UP Key or DOWN Key to display Fn013.
DATA/
Press the DATA/SHIFT Key for approximately one
second. PGSEt will be displayed.
Press the MODE/SET Key.
The value of the multiturn limit setting in the absolute
encoder will be made the same as the setting of
Pn205.
DATA/
When unifying the values has been completed, donE
will flash on the display for approximately one sec-
ond.
After displaying donE, the display will return to the
PGSEt display.
Press the DATA/SHIFT Key for approximately one
second to return the display to Fn013.