3.7

EMC Installation Conditions

This section gives the installation conditions that were used for EMC certification testing.
The EMC installation conditions that are given here are the conditions that were used to pass
testing criteria at Yaskawa. The EMC level may change under other conditions, such as the
actual installation structure and wiring conditions. These Yaskawa products are designed to be
built into equipment. Therefore, you must implement EMC measures and confirm compliance
for the final equipment.
The applicable standards are EN 55011 group 1 class A, EN 61000-6-2, EN 61000-6-4, and
EN 61800-3 (category C2, second environment).
• Three-Phase, 200 VAC
Power supply:
Three-phase, 200 VAC
Symbol
I/O Signal Cable
Safety Function Device Cable
Servomotor Main Circuit Cable
Encoder Cable
Main Circuit Power Cable
Noise
filter
Surge
absorber
PE
Cable Name
Brake power supply
SERVOPACK
U, V, and W
L1, L2, and L3
L1C and L2C
CN2
CN1
CN8
Clamp
Clamp
Host
Safety
controller
function device
Specification
Shielded cable
Shielded cable
Shielded cable
Shielded cable
Shielded cable

3.7 EMC Installation Conditions

Shield box
Brake
Servomotor
Encoder
Clamp
PE
3
3-9