YASKAWA SGD7S Product Manual page 591

E-7s servopack with analog voltage/pulse train references
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

Parameter
Name
No.
Output Signal Selec-
2
tions 1
/COIN (Positioning Completion Output) Signal Allocation

n.
X
Pn50E
/V-CMP (Speed Coincidence Detection Output) Signal Allocation

n.
X
/TGON (Rotation Detection Output) Signal Allocation

n.
X
/S-RDY (Servo Ready) Signal Allocation

n.X
Output Signal Selec-
2
tions 2
/CLT (Torque Limit Detection Output) Signal Allocation

n.
X
Pn50F
/VLT (Speed Limit Detection) Signal Allocation

n.
X
/BK (Brake Output) Signal Allocation

n.
X
/WARN (Warning Output) Signal Allocation

n.X
Setting
Setting
Range
Unit
0000 to
6666
0
Disabled (the above signal output is not used).
1
Output the signal from the CN1-25 or CN1-26 output terminal.
2
Output the signal from the CN1-27 or CN1-28 output terminal.
3
Output the signal from the CN1-29 or CN1-30 output terminal.
4
Output the signal from the CN1-37 output terminal.
5
Output the signal from the CN1-38 output terminal.
6
Output the signal from the CN1-39 output terminal.
The allocations are the same as the /COIN (Positioning Comple-
0 to 6
tion) signal allocations.
The allocations are the same as the /COIN (Positioning Comple-
0 to 6
tion) signal allocations.
The allocations are the same as the /COIN (Positioning Comple-
0 to 6
tion) signal allocations.
0000 to
6666
0
Disabled (the above signal output is not used).
1
Output the signal from the CN1-25 or CN1-26 output terminal.
2
Output the signal from the CN1-27 or CN1-28 output terminal.
3
Output the signal from the CN1-29 or CN1-30 output terminal.
4
Output the signal from the CN1-37 output terminal.
5
Output the signal from the CN1-38 output terminal.
6
Output the signal from the CN1-39 output terminal.
The allocations are the same as the /CLT (Torque Limit Detection
0 to 6
Output) signal allocations.
The allocations are the same as the /CLT (Torque Limit Detection
0 to 6
Output) signal allocations.
The allocations are the same as the /CLT (Torque Limit Detection
0 to 6
Output) signal allocations.
Continued from previous page.
Default
Applicable
Setting
Motors
Enabled
3211
All
0000
All
14.1 List of Parameters
14.1.2 List of Parameters
When
Classi-
Refer-
fication
ence
After
Setup
restart
Reference
page 6-36
Reference
page 6-26
Reference
page 6-10
Reference
page 6-11
After
Setup
restart
Reference
page 6-71
Reference
page 6-44
Reference
page 5-37
Reference
page 6-10
Continued on next page.
14-27
14

Advertisement

Table of Contents
loading