Resetting Method For Forced Stops - YASKAWA SGD7S Product Manual

E-7s servopack with analog voltage/pulse train references
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

6.17.3

Resetting Method for Forced Stops

This section describes the reset methods that can be used after stopping operation for an
FSTP (Forced Stop Input) signal.
If the FSTP (Forced Stop Input) signal is OFF and the /S-ON (Servo ON Input) signal is input,
the forced stop state will be maintained even after the FSTP signal is turned ON.
Turn OFF the /S-ON signal to place the SERVOPACK in the base block (BB) state and then turn
ON the /S-ON signal again.
FSTP signal
/S-ON signal
SERVOPACK
state
ON (normal operation)
(forced stop request)
Operating state

6.17.3 Resetting Method for Forced Stops

OFF
ON (normal operation)
OFF
ON
Forced stop state:
BB state
FSTP is displayed.
6.17 Forcing the Motor to Stop
ON
Operating state
6
6-107