4.3 Wiring the Power Supply to the SERVOPACK
4.3.4 Power Supply Wiring Diagrams
• Wiring Example for Single-Phase, 100-VAC Power Supply Input:
SGD7S-R70F, -R90F, -2R1F, or -2R8F
4-20
R
T
1QF
3SA
1FLT
2KM
1Ry
Servo power
Servo power
ON
1KM
1Ry
1KM
1QF:
Molded-case circuit breaker
1FLT:
Noise Filter
1KM:
Magnetic Contactor (for control power supply)
2KM:
Magnetic Contactor (for main circuit power supply)
SERVOPACK
L1
L2
1KM
L1C
L2C
B1/
(For servo alarm
B2
display)
1PL
OFF
1KM
1SA
2KM
2SA
1Ry:
1PL:
1SA:
2SA:
3SA:
1D:
+24 V
CN1
1Ry
+
31
ALM
ALM
32
1D
0 V
Relay
Indicator lamp
Surge Absorber
Surge Absorber
Surge Absorber
Flywheel diode