40

OPERATOR WARNING AND INDUCEMENT

OPERATOR WARNING AND INDUCEMENT
1. Warning signal for Emission failure
Engine warning signal for emission failures must be indicated and shall not be the same as the warning used for the
purposes of malfunction or other engine maintenance, though it may use the same warning system.
All the emission failures are also recorded in the ECU.
Emission failures are related to the PM control diagnosis (PCD) and NOx control diagnosis (NCD), as mentioned below.
PCD / NCD
Monitor type
Removal of the DPF system
PCD
Loss of function of the DPF system
Failures of the PCD system
Removal of the EGR system
NCD
Removal of the MAF sensor
A The system has operator inducement strategy in order to comply with EU stage V emission regulations.
2. Warning Indicator
The malfunction indicator lamp behaves as shown below.
Refer to the operator's manual for the warning / inducement indicator strategy of the each machine which the engine is
installed.
(1) Usual warning (Emission failure not detected)
(2) Emission failure and other warnings detected
Subject component
Inducement
DPF system
No applicable
EGR system
Applicable
MAF system
P-code
SPN
FMI
P1A28
3936
7
P3015
3936
2
P2455
3251
3
U0076
523578
2
P0102
132
4