18.3.5

Scanner System: blurred image, blotchy image

A. Typical Faulty Images
B. Troubleshooting Procedure
Step
Section
1
Original
Original Cover
2
Original Glass
3
2nd/3rd Mirrors Car-
riage
4
5
4036fs4031c0
Check Item
Original does not lie flat.
Original Cover does not lie flat.
Original Glass tilts.
Scanner is not aligned with the
2nd/3rd Mirrors Carriage.
The problem has been eliminated
through the checks of steps up to 4.
18. Image quality problem
Result
Action
YES
Change original.
YES
Change Original Cover if it
is deformed or hinges are
broken.
YES
Position Original Glass
correctly. Check original
loading position.
YES
Perform "Focus Position-
ing of the Scanner and
2nd/3rd Mirrors Carriage"
and "Scanner Position
Adjustment."
NO
Change Scanner Assy.
Change CCD Unit.