7. Test mode
7.3.8
Storage Roller/Rolls Spacing
S1-FN: ON
Pressed
S2-FN: ON
Separated
7.3.9
Elevator Tray Operation
S1-FN: ON
Goes up until the Elevator Tray Upper Limit Sensor PQ (PWB-D FN) is blocked.
S2-FN: ON
Goes down until the Elevator Tray Upper Limit Sensor PQ (PWB-D FN) is
unblocked.
7.3.10
Sensor Test
Elevator Tray Upper Limit Sensor PQ (PWB-D FN)
Storage Sensor (PC3-FN)
Lower Entrance Sensor(PC2-FN)
Upper Entrance Sensor(PC4-FN)
18
Sensor
Field Service Ver. 1.0 Jul. 2005
State
1
❍
❍
Unblocked
❍
❍
Blocked
❍
●
Blocked
●
❍
Blocked
●: ON ❍: OFF
LED
2
3
4
❍
●
●
❍
❍
❍
❍
❍