Misfeed At Duplex Transport Section (Ad) - Konica Minolta bizhub C250 Service Manual

Hide thumbs Also See for bizhub C250:
Table of Contents

Advertisement

Field Service Ver. 3.0 Aug. 2006
15.3.9
Misfeed at Duplex transport section (AD-503)
A. Detection Timing
Type
Detection of
The Duplex Unit Transport Sensor 2 (PC2 DU) is not blocked even after the lapse
misfeed at Duplex
of a given period of time after the paper has blocked the Duplex Unit Transport
Transport section
Sensor 1 (PC1 DU).
The Duplex Unit Transport Sensor 1 (PC1 DU) is not unblocked even after the
lapse of a given period of time after it has been blocked by the paper.
The Duplex Unit Transport Sensor 2 (PC2 DU) is not unblocked even after the
lapse of a given period of time after it has been blocked by the paper.
Detection of paper
Duplex Unit Transport Sensor 1 (PC1 DU) or Duplex Unit Transport Sensor 2
left in Duplex
(PC2 DU) is blocked when the Main Power Switch is turned ON, a door or cover is
Transport Section
opened and closed, or a misfeed or malfunction is reset.
B. Action
Duplex Unit Transport Sensor 1 (PC1 DU)
Duplex Unit Transport Sensor 2 (PC2 DU)
Duplex Unit Switchback Motor (M1 DU)
Duplex Unit Transport Motor (M2 DU)
Step
1
Initial check items
2
PC1 DU I/O check, Sensor check
3
PC2 DU I/O check, Sensor check
4
M1 DU operation check
5
M2 DU operation check
6
Change PWB-A DU
7
Change PWB-M
Relevant Electrical Parts
Action
Description
Duplex Control Board (PWB-A DU)
Mechanical Control Board (PWB-M)
WIRING DIAGRAM
Control Signal
PWB-A DU PJ4A DU-1 to 4
PWB-A DU PJ5A DU-1 to 4
15. Jam Display
Location (Electri-
cal Component)
Q-21
Q-21
R-22
R-22
411