14. Mechanical adjustment
14.2 Scanner Position Adjustment
This adjustment must be made in the following case:
• The Scanner Drive Cables have been rewound.
• Focus Positioning of the Scanner and Mirrors Unit must be completed.
[1]
100 mm
[3]
200 mm
390
4038F3C509DA
[2]
[3]
4038F3C510DA
Field Service Ver. 3.0 Aug. 2006
1. Slide the Mirrors Unit [1] to the posi-
tion shown on the left.
2. Secure the Scanner [2] in the posi-
tion shown on the left using the two
Scanner positioning screws [3].
3. Make the Feed Direction Adjustment.
See P.304