Scanner Assy - Konica Minolta bizhub C250 Service Manual

Hide thumbs Also See for bizhub C250:
Table of Contents

Advertisement

Field Service Ver. 3.0 Aug. 2006
[12]
[13]
[4]
[1]
6.3.36

Scanner Assy

[2]
[14]
[11]
4037F2C134DB
[1]
[3]
[2]
[1]
4038F2C524DA
[1]
4038F2C135DB
8. Remove two Screws [11], Set screw
[12], Damper [13], and remove the
Scanner Motor [14].
B. Reinstallation Procedure
1. Temporarily secure the Scanner
Motor Assy [2] using three Screws
[1].
2. Hook the Tension spring [3].
3. With the Scanner drive gear set
screw located on the right-hand side
as shown on the left, slide the Scan-
ner Motor Assy to the left and check
that it is returned to the original posi-
tion by the tension of the spring. Per-
form this step three times.
4. Securely tighten the three Screws to
fix the Scanner Motor Assy [2] into
position.
5. Connect the Connector and fix the
Harness to the Wire Saddle.
1. Remove the Original Glass.
See P.81
2. Move the Scanner Assy [1] to the
notch position shown in the left illus-
tration, and remove the mounting
screws [2] at front and rear.
6. Other
129

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub c252

Table of Contents