Konica Minolta bizhub C250 Service Manual page 117

Hide thumbs Also See for bizhub C250:
Table of Contents

Advertisement

5. Firmware upgrade
Error code
Control panel
Error concerning the network
0x00111001
• It cannot be connected to the server.
Error concerning the network
0x00111100
• Communication Timeout.
Error concerning the network
0x00111101
• Disconnection occurred
Error concerning the network
0x00111110
• The network is not connected.
Error concerning the network
0x00110010
• Others
FTP error
0x00001###
• Reply code when it failed to be con-
nected
FTP error
0x00002###
• Error reply code for the User command
or Pass command
FTP error
0x00003###
• Error reply code for CWD command
FTP error
0x00004###
• Error reply code for the TYPE com-
mand.
FTP error
0x00005###
• Error reply code for the PORT com-
mand.
FTP error
0x00006###
• Error reply code for the PASV com-
mand.
FTP error
0x00007###
• Error rely code for the RETR com-
mand.
• It cannot be accepted because of the
0x1000 0100
job currently being executed.
• ISW being executed by other method.
• It cannot be accepted because the
0x10000101
sub-power is OFF.
• The Internet ISW is already being exe-
0x10000102
cuted.
• It failed to prohibit the job. (It failed to
lock the operation.)
→ It failed to lock the job because the
0x10000103
operation is already locked with
PSWC, etc.
• There is no space for F/W data to be
0x10000104
downloaded.
0x10000106
• Check sum error
74
Description
Field Service Ver. 3.0 Aug. 2006
Countermeasure
• Check the network environment of the
User.
• Check to see if the FTP server oper-
ates normally.
• Check the network environment of the
User.
• Check to see if the FTP server oper-
ates normally.
• Check to see if FTP server normally
operates.
• Check the IP address, User's name,
etc.
• Check to see if FTP server operates
normally.
• Check to see if FTP server operates
normally.
• Check to see if FTP server operates
normally.
• Set the PASV mode to "Invalid", and try
it again.
• Check to see if FTP server operates
normally.
• Wait for about 30 minutes and try it
again.
• Wait for the current job to be completed
and try it again.
• Turn sub-power ON and try it again.
• Wait for the current Internet ISW to be
completed.
• Check if the following setting is set to
"Valid".
[Service Mode] → [Internet ISW] →
[Internet ISW setting]
• If the above process does not solve the
problem, inform the corresponding
error code to the KONICA MINOLTA.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub c252

Table of Contents