Field Service Ver. 3.0 Aug. 2006
(3) Failing to update the Firmware after downloading has started
1. Once Firmware updating has started, the ROM in the Copier will be deleted.
When it failed right after updating has started, restart the Copier, and shift to the
standby screen to retry downloading.
2. When updating on the control panel, touch [settings] on the standby screen, and check
the Network settings again.
Touch [Download], and restart the Internet ISW.
NOTE
• Return to the standby screen without fail after turning the Main power OFF/ON if
the Firmware is not updated.
• Firmware can be updated with the Compact flash with the Main power OFF.
D. Confirming the Firmware Version
1. Call the Service Mode to the screen.
2. Select the [Firmware Version].
3. Check if the Firmware Version is updated.
3. Firmware upgrade