Konica Minolta bizhub C250 Service Manual page 639

Hide thumbs Also See for bizhub C250:
Table of Contents

Advertisement

3. Firmware upgrade
Error code
Control panel
File access error
• The file downloaded has an error.
• The header of the file which has been
read has an error.
0x10000107
• The size of the file to be downloaded is
too large.
• When it is identified to be the different
type of F/W.
• The area F/W is stored is destroyed,
0x10000108
and another ISW is necessary.
The temporary error when running the
subset
• When starting the Internet ISW in a
normal program, the rebooting will start
and the Internet ISW will be executed
0x20000000
with the subset program.
During the process by the subset pro-
gram, it has to be in the "Failed" status
unless the Internet ISW is successfully
conducted. This code is used tempo-
rarily to make it in error status.
36
Description
Field Service Ver. 3.0 Aug. 2006
Countermeasure
• Check to see if the downloaded F/W is
of the correct type.
• Wait until ISW is automatically exe-
cuted on MFP side.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub c252

Table of Contents