Field Service Ver. 3.0 Aug. 2006
6.4.13
Original Glass
[1]
6.4.14
CCD Sensor
[1]
[2]
[1]
[3]
1. Using a soft cloth dampened with
4038F2C183DA
1. Remove the Original Glass.
See P.81
2. Remove seven Screws [1] and CCD
[1]
4038F2C069DA
3. Remove two hooks [3] and the lens
[4]
4038F2C184DA
alcohol, wipe the Original Glass [1]
clean of dirt.
Unit protective cover [2].
cover [4].
6. Other
161