16. Malfunction code
16.5.10
C2451: Transfer Cleaner Unit New Article Release
Mechanical Control Board (PWB-M)
Step
1
Reinstall Unit
2
Change PWB-M
16.5.11
C2551: Abnormally low toner density detected Cyan TCR Sensor
16.5.12
C2553: Abnormally low toner density detected Magenta TCR Sensor
16.5.13
C2555: Abnormally low toner density detected Yellow TCR Sensor
Imaging Unit /C
Imaging Unit /M
Imaging Unit /Y
Toner Supply Motor C/K (M6)
Toner Supply Motor Y/M (M7)
Step
Perform image troubleshooting procedure if
1
image density is low.
Clean the TCR Sensor window on the
2
underside of the Imaging Unit if dirty
M6, M7 operation check
3
4
Reinstall Imaging Unit
5
Change Imaging Unit
6
Change PWB-M
7
Change PWB-MFP.
446
Relevant Electrical Parts
Action
Relevant Electrical Parts
Action
Field Service Ver. 3.0 Aug. 2006
WIRING DIAGRAM
Control Signal
—
—
Mechanical Control Board (PWB-M)
MFP Control Board (PWB-MFP)
WIRING DIAGRAM
Control Signal
—
—
PWB-M CNDM2-10 to 13 (M6)
PWB-M CNDM3-10 to 13 (M7)
—
—
—
—
Location (Electri-
cal Component)
—
—
Location (Electri-
cal Component)
—
—
C-20