Disassembly Of The Image Reading Section; Removal Of The Original Cover Set Sensor; Removal Of The Upper Cover Assy. (Original Glass; Removal Of The Scanner Motor - Konica Minolta Di1610 Service Manual

Hide thumbs Also See for Di1610:
Table of Contents

Advertisement

3-4.

Disassembly of the Image Reading Section

(1)

Removal of the Original cover set sensor

1. Remove the Original Cover.
2. Remove the Control Panel.
☞ D-7
(2)

Removal of the Upper Cover Assy. (Original Glass)

1. Remove the Original Cover.
2. Remove the Control Panel.
☞ D-7
(3)

Removal of the Scanner Motor

1. Remove the Original Cover.
2. Remove the Upper Cover Assy. (Original Glass).
☞ D-18
3. Remove the Left Cover.
☞ D-7
3. Remove the Original cover set sensor.
4980D073AA
3. Remove the six screws, and remove the Upper
Cover Assy. (Original Glass).
4980D017AB
4. Unplug one connector from the Scanner Motor.
4980D007AA
D-18