Machine Parameter Adjustment; Setting The Machine Parameters; Clearing The Machine Parameters - Muratec MFX-1330 Field Engineering Manual

Hide thumbs Also See for MFX-1330:
Table of Contents

Advertisement

3.2 Machine Parameter Adjustment

3.2.1 Setting the Machine Parameters

These switches are used to program internal machine parameters. The primary back up battery maintains
these settings if power is lost.
1. From standby, press MENU, *, 0, 0.
Set Parameters
2. Press ENTER.
3. Call up the desired switch by pressing
Select Parameters
000:00000000
4. Press ENTER.
001:01010000
01010000
Bit No.
76543210
5. To navigate through the machine parameter settings:
• The bits are ranged from 7 (left) to 0 (right).
• Press
or
• Press 0 or 1 on the numeric keypad, or
• Press ENTER to save the setting of the displayed parameter and return to the machine parameter
edit screen.
• Press MENU not to save the setting of the displayed parameter.
6. If you want to set other machine parameters, repeat step 3-5. Otherwise, proceed to step 7.
7. Press RESET to return the machine to standby.
Note: You can confirm the initial setting of each Machine parameter by the Machine Parameters List.
The Machine Parameters List will be printed by pressing MENU, *, 1, 0.

3.2.2 Clearing the Machine Parameters

Resets the machine parameters to factory defaults.
1. From standby, press MENU, *, 0, 0,
Clear Parameters
2. Press ENTER.
Clear Parameters
Yes → Enter
3. Press ENTER. The machine parameters will reset to factory defaults.
Note: To finish the operation without clearing the parameters, press CANCEL.
4. Press RESET to return the machine to standby.
/ /Enter
or
, or by pressing the numeric keypad.
of the cursor key to move the cursor.
.
/ /Enter
or
, to change the bit value.
3-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

F-300