Muratec MFX-1330 Field Engineering Manual page 32

Hide thumbs Also See for MFX-1330:
Table of Contents

Advertisement

Machine Parameter 000 ∼ 006 --- Factory use only
Machine Parameter 007
Initial
Switch
Setting
7
0
DRAM capacity indication
(Spare)
6
0
DRAM capacity indication
(Slot 2)
5
0
4
0
3
0
DRAM capacity indication
(Slot 1)
2
0
1
0
0
0
DRAM capacity indication
on the Main PCB
Machine Parameter 008 and 009 --- Factory use only
Machine Parameter 010
Initial
Switch
Setting
7
0
ADF scanner registration
adjustment (Horizontal)
6
0
5
0
Adjusts the start point to
4
0
scan the document.
3
0
The plus setting increases
2
0
the left margin and the minus
1
0
setting decreases it.
0
0
1 step = 2 / 600 dpi
Note: These values
are factory set and should
not be adjusted unless
instructed by a Muratec
technical representative.
Adjust
This switch indicates the DRAM capacity.
(This switch is read only, do not set any character)
You can see the memory capacity by how many "1"
is indicated on the LCD. One "1" means 8MB.
For example, if three "1" are indicated,
i.e. "00000111", the DRAM capacity is
8MB × 3 = 24MB.
Adjust
Switch
127 steps 01111111
(0.0847 mm)
-127steps
3-4
Usage/Comments
Usage/Comments
76543210
Settings
+10.76 mm
:
00100000
+2.71 mm
:
00010000
+1.36 mm
:
00001000
+0.68mm
:
00000000
0 mm
:
10001000
-0.68 mm
:
10010000
-1.36 mm
:
10100000
-2.71 mm
:
11111111
-10.76 mm
Initial setting

Advertisement

Table of Contents
loading

This manual is also suitable for:

F-300

Table of Contents