Muratec MFX-1330 Field Engineering Manual page 83

Hide thumbs Also See for MFX-1330:
Table of Contents

Advertisement

Memory Switch 14 --- Factory use only
Memory Switch 15 --- Transmission
Initial
Switch
Setting
7
0
Program individual autodialer
attributes
0: No
1: Yes
6
0
Factory use only
5
0
Factory use only
4
0
Factory use only
3
0
Factory use only
2
0
Sending RTC signal when
transmission is canceled
0: Yes
1: No
1
1
Cancel redial if T.4.1 or T.4.4
error occurs
0: Yes
1: No
0
1
Action after EOR signal
0: Continue
1: Discontinue
Memory Switch 16 --- Transmission
Initial
Switch
Setting
7
0
Factory use only
6
0
Factory use only
5
0
Factory use only
4
0
Factory use only
3
1
Additional data on TTI
transmit
0: No
1: Yes
2
1
Subscriber ID transmit
0: No
1: Yes
1
1
TTI (name) transmit
0: No
1: Yes
0
0
Factory use only
Memory Switch 17 ∼ 19 --- Factory use only
Adjust
Allows individual setting of memory switches 10 as
attribute 1, 11 as attribute 2, 12 as attribute 3 and
13 as attribute 4 when one-touch and speed dial
locations are programmed. (Refer to page 3-69 for
settings.)
RTC signal is sent at the end of the transmission.
When set at "0", the machine will send the RTC if
the transmission is canceled. No error will occur.
When set at "1", an error will occur because RTC
will not be sent at the end of a canceled
transmission.
When set at "0", if a T.4.1 or T.4.4 error occurs, the
machine will not retry the transmission.
Sets action after receiving PPR four times at 2400
bps.
Adjust
When set at "0", the transmission of the additional
data (time, the number of pages, file number, etc)
is disabled.
Note: This switch is available only when Memory
switch 012, bit 4 and/or Memory switch 13, bit 5 is
available.
When set at "0", the transmission of the subscriber
ID is disabled.
Note: This switch is available only when Memory
switch 12, bit 4 and/or Memory switch 13, bit 5 is
available.
When set at "0", the transmission of the name that
is stored in the unit is disabled.
Note: This switch is available only when Memory
switch 12, bit 4 and/or Memory switch 13, bit 5 is
available.
3-55
Usage/Comments
Usage/Comments

Advertisement

Table of Contents
loading

This manual is also suitable for:

F-300