SENSOR PDS / DPS

1) Remove the Chassis FBS. (See page 5-32)
2) Remove five Frame upper mounting screws, and then remove the Frame upper.
3) Remove the Sensor stopper and disconnect the connector, and then remove the SENSOR PDS/DPS.
Ground wire
Sensor stopper
ROLLER EXIT
1) Remove the Chassis FBS. (See page 5-32)
2) Remove the Frame upper.
3) Remove one E-ring, and then remove the BRG exit.
4) Slide out the ROLLER EXIT.
NOTE: When reattaching the BRG exit, align its cutout with the cutout of the Frame upper's holder.
TX gear 20
Ground wire
Sensor DPS
Frame upper
Frame upper
Roller exit
5-56
5-56
Sensor PDS
Sensor stopper
BRG Exit
E-ring
BRG Exit