Setting The Watchdog Timer For Monitoring After A Stop Error (Fatal System Error); Figure 6.2 [Add A Port] Dialog Box (Snmp) - Fujitsu PRIMEQUEST 1000 Series Installation Manual

Hide thumbs Also See for PRIMEQUEST 1000 Series:
Table of Contents

Advertisement

PRIMEQUEST 1000 Series Installation Manual
CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E)

FIGURE 6.2 [Add a Port] dialog box (SNMP)

5. Enter the port number used by SNMP. Then, click the [OK] button.
6. Click the [OK] button in the [Windows Firewall] window.
6.3.6
Setting the Watchdog Timer for monitoring after a STOP error (fatal
system error)
If a STOP error (fatal system error) occurs in the system, the following situation results.
- After you select [Partition] - [Power Control] from the MMB Web-UI, the window displays "Stop Error"
under [System Progress] for the relevant partition.
- The system acquires a memory dump.
You can set monitoring with the Watchdog Timer to perform recovery after the system freezes or otherwise becomes
unresponsive in the above event.
Immediately after the specified time elapses, the MMB performs a Hard Reset to reboot the operating system.
Operations
1. Open the following file:
PSA installation folder\etc\opt\FJSVpsa\usr\pnwatchdog.conf
Example: C:\fujitsu\FJSVpsa\etc\opt\FJSVpsa\usr\pnwatchdog.conf
2. Specify the value of the following key. The default is 0.
Section: [WATCHDOG]
Key: [TIMER]
Setting value (unit: seconds): 0 (Watchdog Timer disabled), 1 to 6000 (Watchdog Timer monitoring time)
157