Fujitsu PRIMEQUEST 1000 Series Installation Manual page 300

Hide thumbs Also See for PRIMEQUEST 1000 Series:
Table of Contents

Advertisement

PRIMEQUEST 1000 Series Installation Manual
APPENDIX E Notes on VMware Installation
\: This indicates that there is no line feed.
In the above example, vmnic0 is used for the PSA-to-MMB communication LAN, and vmnic1is used for the
management LAN.
Configuring the management LAN
1. Use vswif0, which exists by default immediately after the installation of the operating system, for the interface
of the management LAN.
Execute the esxcfg-vswif command to confirm the status of vswif0.
# esxcfg-vswif -l
Name Port Group/DVPort IP Family IP Address \
Netmask Broadcast Enabled TYPE
vswif0 Service Console IPv4 N/A \
N/A N/A true NONE
\: This indicates that there is no line feed.
The above example shows that vswif0 has been set for the Port Group name of "Service Console."
2. Execute the esxcfg-vswitch command to confirm the status of the virtual switch.
# esxcfg-vswitch -l
Switch Name Num Ports Used Ports Configured Ports \
MTU Uplinks
vSwitch0
1500
PortGroup
VM Network
Service Console 0
\: This indicates that there is no line feed.
The above example shows that Service Console exists in vSwitch0, and the physical adapter is vmnic0.
3. Disconnect the physical adapter from vSwitch0, and then connect the physical adapter vmnic1, which is used
for the management LAN, to vSwitch0.
Execute the esxcfg-vswitch command to disconnect the physical
adapter vmnic0 from vSwitch0.
# esxcfg-vswitch -U vmnic0 vSwitch0
# esxcfg-vswitch -l
Switch Name Num Ports Used Ports Configured Ports \
MTU
Uplinks
vSwitch0 64
1500
64
2
vmnic0
Name VLAN ID Used Ports Uplinks
0
0
1
2
64 \
vmnic0
vmnic0
64 \
272
C122-E107-09EN