Fujitsu PRIMEQUEST 1000 Series Installation Manual page 169

Hide thumbs Also See for PRIMEQUEST 1000 Series:
Table of Contents

Advertisement

PRIMEQUEST 1000 Series Installation Manual
CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E)
Example of input
[PSATRAP]
PSATRAP_SET=1
2. Set trap destinations in the snmpd.conf file.
For details, see
Editing
3. Restart PSA to apply the settings.
Syntax
#/sbin/service
#/sbin/service
Editing snmpd.conf
# vi /etc/snmp/snmpd.conf
Add the following lines according to the SNMP version used.
* The lines of definitions can be in any order.
trapsink HOST [COMMUNITY [PORT]]
trap2sink HOST [COMMUNITY [PORT]]
trapsess SNMPCMD_ARGS HOST[:PORT]
The following describes the settings in detail.
SNMPv1/SNMPv2 trap setting
trapsink HOST [COMMUNITY [PORT]]
trap2sink HOST [COMMUNITY [PORT]]
The setting defines the host receiving the trap (i.e., the trap destination).
- A Cold Start trap is sent to the defined host during snmpd startup. If the partition is set to send SNMP traps,
a trap is sent from the partition following any authentication failure.
- You can specify multiple trap destinations by specifying multiple hosts on the trapsink and trap2sink lines.
As an alternative to specifying COMMUNITY, you can specify a character string on the trapcommunity line.
The trapcommunity command defines a default community character string for sending traps. To use
trapcommunity to set a community character string, specify the string before the trapsink and trap2sink lines.
trapcommunity STRING
- As an alternative to specifying PORT, you can use the general-purpose SNMP trap port (162).
snmpd.conf.
y30FJSVpsa stop
y30FJSVpsa start
141
# SNMPv1 trap setting
# SNMPv2 trap setting
# SNMPv3 trap setting
# SNMPv1 trap setting
# SNMPv2 trap setting
# Community name setting
C122-E107-09EN