Installing The Pshed Plugin Driver - Fujitsu PRIMEQUEST 1000 Series Installation Manual

Hide thumbs Also See for PRIMEQUEST 1000 Series:
Table of Contents

Advertisement

PRIMEQUEST 1000 Series Installation Manual
CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E)
6.4.3

Installing the PSHED Plugin driver

The PSHED Plugin driver expands the WHEA (Windows Hardware Error Architecture) functions.
This driver is not automatically installed. Manually install the driver with the batch file (plugin_install.bat) stored
in the following folder.
PSA installation folder \fjpsaplg\plugin_install.bat
(Example: C:\Program Files (x86)\Fujitsu\FJSVpsa\fjpsaplg\plugin_install.bat)
Remarks
The following functions do not work unless the driver is installed:
- Suppression of logging of Correctable Error events to the Event Viewer (Windows system event log)
- State transition to Stop Error for a Blue Screen of Death event ([System Progress] in the [Power Control]
window of the MMB Web-UI)
Notes
- Do not execute the installation batch more than once.
If it is executed more than once, as many PRIMEQUEST PSHED Plugin drivers as the number of times
executed are installed.
- If the installation batch is executed multiple times, no operational problems occur but multiple
PRIMEQUEST PSHED Plugin drivers are displayed by the Device Manager.
In this case, uninstall all the PRIMEQUEST PSHED Plugin drivers and then reinstall one according to the
following procedure. After the reinstallation, the operating system must be restarted.
1. Record the number of times [PRIMEQUEST PSHED Plugin Driver] appears under [System Devices]
in the Device Manager.
2. Execute the following PSHED Plugin driver uninstallation batch as many times as the number recorded
in step 1.
3. Restart the operating system.
4. Confirm that no [PRIMEQUEST PSHED Plugin Driver] appears under [System Devices] in the Device
Manager.
5. Reinstall the PRIMEQUEST PSHED Plugin driver according to
Operations
1. Open the following folder, and double-click [plugin_install.bat].
PSA installation folder \fjpsaplg
(Example: C:\Program Files (x86)\Fujitsu\FJSVpsa\fjpsaplg)
2. Restart the operating system. Then, the driver starts running.
PSHED Plugin driver uninstallation batch storage location:
PSA uninstallation folder \fjpsaplg\plugin_uninstall.bat
(Default. C:\Program Files (x86)\Fujitsu\FJSVpsa\fjpsaplg
\plugin_uninstall.bat)
Operations
166
below.
C122-E107-09EN