CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E)
12. Click [Action] - [Restart] to restart SNMP Service.
Restarting PSA
1. Click [Start menu] - [Administrative Tools] - [Services].
2. Select [PRIMEQUEST Server Agent] in the right side of the window.
3. Select [Action] - [Restart] from the menu bar to restart PRIMEQUEST Server Agent.
How to confirm a trap destination setting
To confirm a trap destination setting, use the standard SNMP Service trap sent to restart SNMP Service in the above
step 12. You can confirm the correct trap setting by checking whether the trap was received.
Remarks
The trap destination must be running both a trap receiving application and a trap manager to be able to receive
standard SNMP Service traps.
The operation performed in step 12 on the trap source machine restarts SNMP Service.
After that operation, a Cold Start trap is posted to the trap receiving application at the trap destination. Cold Start
is a standard SNMP Service trap.
snmptrapd runs on the Linux machine that is the trap destination to receive traps. snmptrapd outputs the following
message to the system log. Confirm that the Linux machine received the trap normally.
Aug 17 14:50:03 pq-server snmptrapd[2600]: 2005-08-17 14:50:03 \
pq-server.fujitsu.com
[192.168.0.162] (via 192.168.0.162) TRAP,
public SNMPv2-SMI::
enterprises.211.1.31.1.2.100.3 Cold Start
\: This indicates that there is no line feed.
6.3.4

Setting the destinations of traps and e-mail via the MMB

You can set the destinations of traps and e-mail via the MMB by using the MMB Web-UI.
For details on MMB trap destinations, see
Configuring Alarm
E-Mail.
Remarks
- Make settings only as needed.
- Linkage to operations management software requires these settings.
6.3.5

Configuring the Windows Firewall

For operation with the Windows Firewall enabled, the following two ports must be set as exceptions to enable them
to send and receive data from the MMB:
- TCP port 24450 used by PSA
- UDP port 161 used via SNMP
Add these ports by using the following procedure.
SNMP v1, community \
Trap (0) Uptime: 0:00:00.00
7.5.2 Configuring
SNMP. For details on e-mail destinations, see
155