Table 6.10 Settings Automatically Added/Changed During Psa Installation - Fujitsu PRIMEQUEST 1000 Series Installation Manual

Hide thumbs Also See for PRIMEQUEST 1000 Series:
Table of Contents

Advertisement

PRIMEQUEST 1000 Series Installation Manual
CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E)
- Even under an REMCS agreement, no software errors are reported.
Remarks
- SVIM installs PSA as it installs the operating system. For details on SVIM, see the ServerView Installation
Manager.
- The installer installs some components for REMCS function on the operating system side during PSA
installation. Only Fujitsu certified service engineers make settings for REMCS.
The following table lists settings for PSA operation. The installer automatically adds or updates these settings
during PSA installation.
Note
Do not change the settings that were automatically added or changed during PSA installation. Otherwise, PSA may
not operate normally.

TABLE 6.10 Settings automatically added/changed during PSA installation

Item
1. Service settings
2. Environment variable
settings
3. Port settings
4. SNMP security settings
5. WMI (Windows
Management
Instrumentation) settings
- PRIMEQUEST Server Agent
- PRIMEQUEST PEM Command Service
- PRIMEQUEST PSA Environment Control Service
- PATH variable: Adds the value used by PSA to the existing
PATH variable.
- FJSVpsa_INSTALLPATH variable: Adds a new variable.
It sets PSA to use the TCP:24450 port.
Security is set for SNMP Service because PSA needs to accept
SNMP packets from the MMB.
The task varies depending on the parameter selected on the [Security] tab
in the [SNMP Service Properties] window during PSA installation.
- With [Accept SNMP packets from any host] selected:
SNMP security is not configured.
- With [Accept SNMP packets from these hosts] selected: If neither
the MMB IP address nor localhost is specified, localhost and
SNMP security are configured.
PSA uses WMI to acquire information on PCI Express cards and
SCSI devices. WMI is installed as standard with Windows.
These settings include settings on the size of memory and number of
internal handles used by WMI to collect this information. If the system
has many LUNs for devices such as RAIDs, it may not have sufficient
memory or internal handles. For this reason, the settings are changed to
the following values:
- Upper limit on memory used: 536,870,912 bytes (default of the
operating system)
- Upper limit on internal handles: 65,536
164
Description
C122-E107-09EN