PRIMEQUEST 1000 Series Installation Manual
CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E)
Remarks
- Execute the SNMP security setting command (setsnmpsec) in the following situations. For details on the
command, see 4.8 SNMP Security Setting Command (setsnmpsec) in the PRIMEQUEST 1000 Series Tool
Reference (C122-E110EN).
- Having installed PSA, you will be changing the SNMP Service security setting from [Accept SNMP
packets from any host] to [Accept SNMP packets from these hosts].
- You will be changing the MMB IP address.
- In the initial startup of PSA following installation, the Web-UI may display the error message "E_33077 PSA
is Not Active. (01:0000)" in the [PSA] window. This happens because PSA requires extra time to acquire
system sensor data only during the initial startup. Wait a few minutes. Then, refresh the display.
- If you change the MMB IP address or the management LAN IP address on the partition, be sure to then restart
PSA. Otherwise, a display error may occur in the [PSA] window of the Web-UI. Moreover, PSA would not
be able to report detected errors.
Notes on configuring Windows Server 2008
- From [Properties] in the Event Viewer, do not change the operation in [When maximum log size is reached]
for the system log or application log to [Do not overwrite events (clear log manually)]. Otherwise, after the
log reaches the maximum log size, no errors are output to the log, so PSA will be unable to detect any errors.
- Do not stop the Windows Print Spooler service. The information collection function of the operating system
uses WMI to collect configuration information. If the Print Spooler service is stopped, the function cannot
collect the correct configuration information because WMI reports an error.
- If the set value of the following registry key is less than 20000 (20 seconds), the system may hang during
operating system shutdown. Be sure to set a value equal to or greater than 20000 (20 seconds).
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control
"WaitToKillServiceTimeout" (Type: REG_DWORD / Default;20000)
You can use the above registry key to specify the wait time (ms) before the service is terminated in the
shutdown sequence.
6.4.1

Configuring the PSA-to-MMB communication LAN

You can configure the PSA-to-MMB communication LAN by using the same procedure as that for Windows Server
2003. For details,
6.3.1 Configuring the PSA-to-MMB communication
6.4.2

Confirming management LAN settings

Make settings for the management LAN. If necessary, also configure any duplication with teaming or GLS, for
example.
After completing the above network settings for the management LAN, perform the operations in
management LAN IP
address.
Note
In the PRIMEQUEST environment, it is necessary to specify OFF for the STP function of the switch that connects
to the management LAN used for communication with the MMB.
LAN.
165
6.4.8 Setting the
C122-E107-09EN