CHAPTER 3 Work before Operating System Installation
Setting item
POST
Enhanced Speed Step
Turbo Boost Technology
Hyper Threading
Active Processor Cores
Virtualization Technology
Adjacent Cache Line Prefetch UEFI-[Device Manager]-
Hardware Prefetch
I/O space assignment
x2APIC (*)
* Only for the PRIMEQUEST 1800E2
Notes
- When using SVIM on the PRIMEQUEST 1800E2 with x2APIC Disabled set, use up to 128 threads of the
operating CPU in the relevant partition.
In order to use up to 128 threads, specify Disabled for Hyper Threading.
- Check whether I/O spaces have been assigned to the SAS device (SAS card, SAS array controller card,
Onboard SAS controller (GSPB), SAS disk unit controller, SAS array disk unit controller) of the relevant
partition.
Also, when installing the OS in the SAN storage unit, confirm that I/O spaces have also been assigned in the
same manner to the FC card (for boot path only).
"Device:SAS" is displayed for an SAS device and "Device:Fibre" is displayed for an FC device. If the I/O
spaces have not been assigned, cancel the LAN and Fibre Channel assignments from the [Configure I/O
Space Assignment] menu.
However, if the OS is to be installed in a storage device in the SAN environment, do not cancel the I/O space
assignment of the FC card to be used for the installation.
- Confirm that the Boot device to be used in the relevant partition has been recognized by the UEFI. For details
on this confirmation, see 5.4 [Boot Manager] Menu in the PRIMEQUEST 1000 Series Tool Reference (C122-
Screen Transitions
MMB Web-UI-[Partition]-
[Partition#x]-[Mode]
UEFI-[Device Manager]-
[Configure CPU]
UEFI-[Device Manager]-
[Configure CPU]
UEFI-[Device Manager]-
[Configure CPU]
UEFI-[Device Manager]-
[Configure CPU]
UEFI-[Device Manager]-
[Configure CPU]
[Configure CPU]
UEFI-[Device Manager]-
[Configure CPU]
UEFI-[Device Manager]-
[Configure I/O Space
Assignment]
UEFI-[Device Manager]-
[Configure CPU]
53
See (the PRIMEQUEST 1000 Series Tool
Reference (C122-E110EN))
1.3.7 [Partition#x] menu,
[Mode] window
5.5.3 [Configure CPU] menu
5.5.3 [Configure CPU] menu
5.5.3 [Configure CPU] menu
5.5.3 [Configure CPU] menu
5.5.3 [Configure CPU] menu
5.5.3 [Configure CPU] menu
5.5.3 [Configure CPU] menu
5.5.1
Configure I/O Space Assignment menu
5.5.3 [Configure CPU] menu
C122-E107-09EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Primequest 1800e2Primequest 1800e

Table of Contents