D-Link xStack DGS-3120 Series Cli Reference Manual page 949

Dgs-3120 series layer 3 managed gigabit ethernet switch
Hide thumbs Also See for xStack DGS-3120 Series:
Table of Contents

Advertisement

®
xStack
DGS-3120 Series Layer 3 Managed Gigabit Ethernet Switch CLI Reference Guide
Parameters
ports - Specify the list of ports to be configured.
<portlist> - Enter the list of ports that will be used for this configuration here.
all - Specify all ports on the Switch.
analyzer_server_id - The ID of a analyzer server.
<value 1-4> - Enter the analyzer server IS here. This value must be between 1 and 4.
interval - (Optional) The maximum number of seconds between successive statistics counters
information.
disable - This new sFlow counter will not export counter until the interval to be set a
appropriate value. If interval is not specified, its default value is disabled.
<sec 20-120> - Enter the maximum number of seconds between successive statistics
counters information here. This value must be between 20 and 120 seconds.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example
Create sFlow counter poller, which sample port 1 to analyzer server 1:
DGS-3120-24TC:admin#create sflow counter_poller ports 1:1 analyzer_server_id 1
Command: create sflow counter_poller ports 1:1 analyzer_server_id 1
Success.
DGS-3120-24TC:admin#
98-5
config sflow counter_poller
Description
This command is used to configure the sFlow counter poller parameters. If the user wants the
change the analyzer_server_id, he needs to delete the counter_poller and creates a new one.
Format
config sflow counter_poller ports [<portlist> | all] interval [disable | <sec 20-120>]
Parameters
ports - Specify the list of ports to be configured.
<portlist> - Enter the list of ports that will be used for this configuration here.
all - Specify all ports on the Switch.
interval - The maximum number of seconds between successive samples of the counters.
disable - Stop exporting counter.
<sec 20-120> - Enter the maximum number of seconds between successive samples of the
counters here. This value must be between 20 and 120.
Restrictions
Only Administrator and Operator-level users can issue this command.