D-Link xStack DGS-3120 Series Cli Reference Manual page 1036

Dgs-3120 series layer 3 managed gigabit ethernet switch
Hide thumbs Also See for xStack DGS-3120 Series:
Table of Contents

Advertisement

®
xStack
DGS-3120 Series Layer 3 Managed Gigabit Ethernet Switch CLI Reference Guide
unit - (Optional) Specify which unit on the stacking system. If it is not specified, it refers to the
master unit.
<unit_id> - Enter the unit ID value. This value must be between 1 and 6.
all - (Optional) When all is specified, the firmware image on all units will be updated.
increment - (Optional) This is only required for system which does not have file system and
only support one configuration file since the download of a configuration will automatically
apply the setting to the system. If increment is specified, the existing configuration will not
be cleared before applying to the new configuration. If it is not specified, the existing
configuration will be cleared before applying to the new configuration.
dest_file - (Optional) Used to identify the parameter "path_filename".
<pathname>- The pathname specifies an absolute pathname on the device file system. If
pathname is not specified, it refers to the boot_up configuration file.
Restrictions
Only Administrator-level users can issue this command.
Example
To download firmware from TFTP:
DGS-3120-24TC:admin# download firmware_fromTFTP 10.54.71.1 src_file px.had
Command: download firmware_fromTFTP 10.54.71.1 src_file px.had
Connecting to server................... Done.
Download firmware...................... Done.
Please wait, programming flash......... Done.
DGS-3120-24TC:admin#
To download configuration from TFTP:
DGS-3120-24TC:admin# download cfg_fromTFTP 10.54.71.1 src_file cfg01.txt
Command: download cfg_fromTFTP 10.54.71.1 src_file cfg01.txt
Connecting to server..................... Done.
Download configuration................. Done.
DGS-3120-24TC:admin#
109-2 upload
Description
This command is used to upload firmware and configuration from device to TFTP server.
Format
upload [cfg_toTFTP [<ipaddr> | <ipv6addr> | <domain_name 255>] dest_file <path_filename
64> {unit <unit_id>} {src_file <pathname>} {[include | exclude | begin] <filter_string 80>
{<filter_string 80> {<filter_string 80>}} {[include | exclude | begin] <filter_string 80>
{<filter_string 80> {<filter_string 80>}} {[include | exclude | begin] <filter_string 80>
{<filter_string 80> {<filter_string 80>}}}}} | log_toTFTP [<ipaddr> | <ipv6addr> |
<domain_name 255>] dest_file <path_filename 64> | attack_log_toTFTP [<ipaddr> |
Do not power off!