multiplier on the transmit interval that sets the TTL in local data LLDPDUs. The multiplier range
is 2-10. The <reinit-seconds> is the delay before re-initialization, and the range is 1-0
seconds.
Default
• interval—30 seconds
• hold—4
• reinit—2 seconds
Format
lldp timers [interval <interval-seconds>] [hold <hold-value>] [reinit
<reinit-seconds>
Mode
Global Config
no lldp timers
Use this command to return any or all timing parameters for local data transmission on ports
enabled for LLDP to the default values.
Format
no lldp timers [interval] [hold] [reinit]
Mode
Global Config
lldp transmit-tlv
Use this command to specify which optional type length values (TLVs) in the 802.1AB basic
management set are transmitted in the LLDPDUs. Use sys-name to transmit the system name
TLV. To configure the system name, see
the system description TLV. Use sys-cap to transmit the system capabilities TLV. Use port-
desc to transmit the port description TLV. To configure the port description, see See
"description" on page 5.
Default
all optional TLVs are included
Format
lldp transmit-tlv [sys-desc] [sys-name] [sys-cap] [port-desc]
Mode
Interface Config
Switching Commands
Managed Switch CLI Manual, Release 8.0.3
]
"snmp-server" on page
v1.0, July 2010
10-41. Use sys-descto transmit
3-172