Setting Calculations - Omron K3HB-H User Manual

Digital indicators
Hide thumbs Also See for K3HB-H:
Table of Contents

Advertisement

5.1 Setting Calculations

The K3HB-S can add, subtract, and display two analog inputs, input A and input B.
Explanation of Functions
■ A
■ B
■ K-A
A
K
■ A+B
■ A-B
A
■ K-(A+B)
K
K-(A+B)
A
B
Calculation and constant K
• Select to use only input A.
• Select to use only input B.
• Select to subtract input A from a constant.
• K can be set to any value.
• This function is useful for applications such as measuring the
height of a workpiece.
K-A
• Select to add input A and B values.
• Select to subtract input B from input A.
• This function is useful for applications such as measuring steps in
B
workpieces.
A-B
• Select to subtract input A and B values from a constant.
• K can be set to any value.
• This function is useful for applications such as measuring the
thickness of a workpiece.
5.1 Setting Calculations
Initial setting level
S
5-9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

K3hb-xK3hb-sK3hb-v

Table of Contents