Omron K3HB-H User Manual page 218

Digital indicators
Hide thumbs Also See for K3HB-H:
Table of Contents

Advertisement

■ Output Response Time
■ Operation Timing Examples
Example 1
The Unit operates as shown
in the diagram to the right
for the settings shown in the
table below.
Calculation
Timing hold mode
Normal
Averaging times (n)
Once
Example 2
The Unit operates as shown
in the diagram to the right
for the settings shown in the
table below.
Calculation
A+B
Timing hold mode
Normal
Averaging times (n)
Once
Sampling and Comparative Output Response Times
The comparative output response time is the sum of the data
processing time and the output (relay or transistor) response time.
● One input
0.5 ms
0.5 ms
R
● Two inputs
0.5 ms
0.5 ms
R
(Note 1.)
For transistor outputs
For one input: OFF
For two inputs: OFF
For relay outputs
The relay operation time of 10 ms is added to the transistor output
response times.
0.5
Input
A
Output
Comparative output response time 0.5 ms + output response time (See note 1.)
0.5
Input
Input A
Input B
Comparative output response time 0.5 ms + output response time (See note 1.)
* The output every 0.5 ms is the comparative output corresponding
to the input change for either input A or input B. The input change
for both inputs is reflected in the comparative outputs every 1 ms.
0.5 ms
R
R
0.5 ms
0.5 ms
R
R
R
ON 1 ms and ON
OFF 1.5 ms
ON 2 ms and ON
OFF 2.5 ms
0.5
0.5
0.5
Input
Input
Input
Output
Output
Output
0.5
0.5
0.5
Input
Input
Input
Input
Output
Output
Output
Output
Data processing
time
Output response
R
time (See note 1.)
Data processing
time
Output response
R
time (See note 1.)
0.5
Input
Input
Output
Output
0.5
0.5
Input
Input
Output
Output
A-27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

K3hb-xK3hb-sK3hb-v

Table of Contents