Omron K3HB-H User Manual page 54

Digital indicators
Hide thumbs Also See for K3HB-H:
Table of Contents

Advertisement

■ K3HB-S Setting Details
RUN Level
Initial Setting Level (
Input Adjustment Level
1)
(
L
3.5 Product Height Measurement and OK/NG Judgement
Shape of workpiece
Displacement
sensor output
Sync sensor
K3HB-S
Display
K3HB-S
Comparative outputs
Parameter
Comparative
set value HH
Comparative
set value H
Comparative
set value L
Comparative
set value LL
✽ Check on the status displays.
0)
L
Parameter
Calculation
Input type A
Scaling input
value A1
Scaling display
value A1
Scaling input
value A2
Scaling display
value A2
Decimal point
position
Parameter
Timing hold
2 mm
Insufficient
R
press-fitting
Far
Near
ON
OFF
0. 00
PASS
Characters Set value
3. 00
2. 00
-2. 00
-3. 00
Characters Set value
cal
0
in-ta
4-20
inp. a 1
4. 000
Z4W-V25R
dsp. a 1
-4. 00
inp. a2
20. 000
dsp. a2
4. 00
dp
,,,. ,,
Characters Set value
tmg-h
s-h
3 mm
Press-fitting
omitted
2. 00
-3. 00
H
LL
Remarks
Example of monitoring in
two stages, at the ±2 mm
and ±3 mm from the
reference.
Remarks
A
Output (mA)
20
4
Displacement
-4
4
(mm)
0
Remarks
Sampling hold
3-15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

K3hb-xK3hb-sK3hb-v

Table of Contents