Omron K3HB-H User Manual page 62

Digital indicators
Hide thumbs Also See for K3HB-H:
Table of Contents

Advertisement

■ K3HB-S Setting Details
RUN Level
Displacement
Displacement
sensor B
sensor A
(20 mA) 29 mm
Displacement sensor
(12 mA) 25 mm
(A) output
(4 mA) 21 mm
(20 mA) 29 mm
Displacement sensor
(12 mA) 25 mm
(B) output
(4 mA) 21 mm
Sync sensor output
ON
K3HB-S display
OFF
ON
H
OFF
K3HB-S
ON
PASS
comparative outputs
OFF
ON
L
OFF
Parameter
Characters Set value
Comparative
set value H
Comparative
set value L
✽ Check on the status displays.
3.8 Step Inspection
3.00
2.80
26.0 mm
25.6 mm
26.4 mm
23.0 mm
22.8 mm
23.2 mm
3. 00
2. 80
3. 20
* The previous judgement result is held until
the Sync Sensor turns ON. (All outputs turn
OFF when RESET input is received.)
Remarks
2. 50
Monitoring a difference of
±0.5 mm for a reference
1. 50
step of 2 mm
3.20
(Carrier movement)
(Carrier movement)
3-23