Section 5 Functions and Operations
5-8
Parameter Setting Procedure
A Press the M [MODE] Key several times
to display the comparative set value to
be changed.
B Press the S [SHIFT] Key to make the
SV display flash.
• The setting can be changed when the
SV display starts to flash.
C Use the S [SHIFT] Key and U [UP]
Key to change the comparative set
value.
D Press the M [MODE] Key to switch to
the next parameter.
• The comparative set value set in C
will be registered.
M
123. 4
- 1 9999
One of the values
between HH and LL
will flash, according to
the displayed
comparative set value.
S
123. 4
- 1 9999
L
123. 4
U
S
123. 0
L
M
123. 4
- 1 9999
LL