Parameter Display Conditions - Omron K3HB-H User Manual

Digital indicators
Hide thumbs Also See for K3HB-H:
Table of Contents

Advertisement

Parameter Display Conditions

Parameter
Characters
Level
name
RUN/adjustment protect
Setting level protect
Protect
Setting change protect
Forced-zero protect
Max./Min. protect
Measurement value
Measurement value/comparative set value HH
RUN
Measurement value/comparative set value H
Measurement value/comparative set value L
Measurement value/comparative set value LL
Bank
Adjustment
Communication write
Calculation
Input type A
Power supply frequency
Scaling input value A1
Scaling display value A1
Scaling input value A2
Scaling display value A2
Input type B
Initialization
Scaling input value B1
Scaling display value B1
Scaling input value B2
Scaling display value B2
Constant K
Decimal point position
Temperature unit
Comparative output pattern
Move to the advanced-function setting level.
Timing hold
ON timing delay
OFF timing delay
Zero-limit
Zero-limit value
Step value
Average type
Input
adjustment
Averaging times
Input compensation input value 1
Input compensation value 1
Input compensation input value 2
Input compensation value 2
Power interruption memory
Comparative set value display
Display refresh period
Display color selection
Display value selection
Display
Automatic display return
adjustment
Position meter type
Position meter upper limit
Position meter lower limit
PV decimal point display
Comparative set value bank
Comparative set value
HH ( :0 to 7)
Comparative set value
H ( :0 to 7)
Comparative set value
Comparative
set value
L ( :0 to 7)
Comparative set value
LL ( :0 to 7)
Bank copy
Linear current type
Linear voltage type
Linear
output
Linear output upper limit
Linear output lower limit
Communications unit No.
Baud rate
Communications data length
Communications
settings
Communications stop bits
Communications parity
Communications wait time
Output test
Test input
Set value initialization
PASS output change
Hysteresis
Output OFF delay
Shot output
Output logic
Output refresh stop
Advanced-
Tare zero
function
Zero-trimming
setting
Previous average comparison
Bank selection
Startup compensation timer
Operation at input error
Standby sequence
Cold junction compensation
Move to the calibration level
<K35-1 to 4>
Event Input
<K34-C1>
Relay Output (H/L)
<K34-C2>
Relay Output (HH/H/L/LL)
<K34-T1/T2>
Transistor Output
<K34-BCD>
BCD Output
<K33-CPA/B>
PASS Output
<K33-L1A/B>
Linear Current Output
<K33-L2A/B>
Linear Voltage Output
<K33-FLK1A/B> RS-232C
<K33-FLK2A/B> RS-485
<K34-DRT>
DeviceNet
Model
Input
<K34-
<K35-1>
<K34-
<K34-
T1>
<K34-
<K35-2>
X
V
S
H
C2>
<K35-3>
C1>
<K34-
BCD>
<K35-4>
T2>
run.pt
set.pt
wt.pt
zr.pt
mm.pt
---
---
---
---
---
bank
cmwt
cal
in-ta
fre
inp.a1
dsp.a1
inp.a2
dsp.a2
in-tb
inp.b1
dsp.b1
inp.b2
dsp.b2
k
dp
d-u
out-p
amoV
tmg-h
on-t
off-t
z-lim
lim-p
step
aVg-t
aVg-n
isi.1
iss.1
isi.2
iss.2
memo
sV.dsp
d.ref
color
disp
ret
pos-t
pos-h
pos-l
pVdp
sV.bnk
sV0.hh
sV0.h
sV0.l
sV0.ll
copy
lset.c
lset.V
lset.h
lset.l
u-no
bps
len
sbit
prty
sdwt
test
init
pass
hys
off-d
shot
out-n
o-stp
t-zr
z-trm
hp-f
bnk-c
s-tmr
s.err
stdby
cjc
cmo
Items marked may not be displayed due to Unit configuration or settings. Others are always displayed.
Displayed if the Unit is connected.
Displayed if the Unit is connected and the setting conditions are met.

Parameter Display Conditions

Unit
Output
<K33-
<K33-
<K33-
<K33-FLK1A>
<K34-
CPA>
L1A>
L2A>
<K33-FLK1B>
<K33-FLK2A>
DRT>
<K33-
<K33-
<K33-
<K33-FLK2B>
L2B>
CPB>
L1B>
PASS output change = PASS or ERR
When the Output Unit is only <CPA/B>, change in PASS output = HH.
When the Output Unit is only <CPA/B>, change in PASS output = H.
When the Output Unit is only <CPA/B>, change in PASS output = L.
When the Output Unit is only <CPA/B>, change in PASS output = LL.
Bank selection = KEY
When the Output Unit is <CPA>, change in PASS output PASS or ERR.
Calculation
B (Always displayed for X/V/H)
Calculation
B (Always displayed for X/V)
Calculation
B (Always displayed for X/V)
Calculation
B (Always displayed for X/V)
Calculation
B (Always displayed for X/V)
Calculation
A or K-A
Calculation
A or K-A
Calculation
A or K-A
Calculation
A or K-A
Calculation
A or K-A
Calculation = K-A or K-(A+B)
When the Output Unit is <CPA>, change in PASS output PASS or ERR.
Setting level protect = 0
Timing hold
NormaL
Timing hold
Normal or sampling
Zero limit = ON
When the Output Unit is <CPA>, change in PASS output PASS or ERR.
Position meter type
Position meter type
Switching banks
When the Output Unit is <CPA>, change in PASS output PASS or ERR.
is the value between 0 and 7 set on the comparative set value bank.
When the Output Unit is only <CPA>, change in PASS output = HH.
is the value between 0 and 7 set on the comparative set value bank.
When the Output Unit is only <CPA>, change in PASS output = H.
is the value between 0 and 7 set on the comparative set value bank.
When the Output Unit is only <CPA>, change in PASS output = L.
is the value between 0 and 7 set on the comparative set value bank.
When the Output Unit is only <CPA>, change in PASS output = LL.
Switching banks
When the Output Unit is <CPA>, change in PASS output PASS or ERR.
When the Output Unit is <CPA>, change in PASS output PASS or ERR.
Timing hold = sampling, peak, or bottom
When the Output Unit is <CPA/B>, change in PASS output PASS or ERR.
When the Output Unit is <CPA/B>, change in PASS output PASS or ERR.
Setting Conditions
OFF
OFF
A-17