5.34 Using the Position Meter

2
pos-t
L
(POS-T)
2
pos-h
L
(POS-H)
2
pos-l
L
(POS-L)
The meter on the right side of the front panel with 20 sections is called
the "position meter" and shows the position of the displayed value
(present value, maximum, or minimum) in relation to any values set
using the position meter upper and lower limits. The position meter
upper and lower limits can be set to any range.
The position meter display pattern is set using the following parameter.
Parameter
Position meter type
pos-t
Position meter upper limit
pos-h
Position meter lower limit
pos-l
*1. The decimal point depends on the "decimal point position"
parameter setting.
*2. The amount that the displayed value differs from the mid-point
between the position meter upper and lower limits (the deviation) is
displayed.
Position meter
Incremental
type
Position meter
upper limit
(100)
Position meter
lower limit
(0)
Present value: 70
* If the position meter lower limit set value is smaller than the position
meter upper limit set value, the top and bottom of the above displays
will be reversed.
* The position meter will not be lit if there is an input error.
5.34 Using the Position Meter
Display adjustment level
Set value
Meaning of set value
off
OFF
inc
Incremental
inc-r
Incremental (reversed)
dev
Deviation (*2)
dev-r
Deviation (reversed)
- 1 9999 to
-19999 to 99999 (*1)
99999
- 1 9999 to
-19999 to 99999 (*1)
99999
Incremental
Deviation
(reversed)
Present value: 70
Present value: 85
X
V
S
H
Deviation
(reversed)
Present value: 85