Advertisement

5.29 Holding Maximum and Minimum Values

Max. value
Min. value
Measuring
Measurement status
Power supply
● Switching Maximum and Minimum Value Displays
Each time the
[MAX/MIN] Key is pressed in RUN level, the PV display switches as follows: present
value
maximum value
Present value
1234.5
90000
* If input error enable (s.err) is ON and a sensor error occurs, the input error will be displayed on the
maximum and minimum display.
The input error is cleared by a RESET input or by pressing the
● Power Interruption Memory
Each time the
maximum and minimum values recorded while a measurement is
being performed will be displayed.
• Maximum and minimum values are not affected when forced-zero
and tare zero are executed or cleared.
Initializing
Measuring
minimum value
present value.
MAX value
Max
3012.6
This function can be used to hold the maximum and minimum values
during power interruptions. The setting choices are hold and no hold.
This function can control maximum and minimum value fluctuations
even if device power is interrupted.
5.29 Holding Maximum and Minimum Values
[MAX/MIN] Key is pressed at the RUN level, the
Measuring
Measurement stopped
MIN value
Min
90000
*
[MAX/MIN] Key for at least 1 s.
X
V
S
H
Initializing
Measuring
985.7
90000
*
5-75