Sampling and Comparative Output Response Times

■ Output Refresh Period
A-26
The K3HB-S sampling and comparative output response times depend
on the calculations, timing hold type, and, for simple averaging, the
averaging times. Refer to the following description for details.
The K3HB-S repeats input reads, calculation, and judgement output
processing. The output refresh period differs depending on whether
there are one or two inputs, as outlined below.
● One input
0.5 ms
0.5 ms
Input
Input
Input A
or
Input B
Output
Input read
Output refresh
● Two inputs
0.5 ms
0.5 ms
Input
Input
Input A
Input B
Output
Input read
Output refresh Every 0.5 ms
0.5 ms
Input
Input
Input
Output
Output
Output
Output
Every 0.5 ms
Every 0.5 ms
0.5 ms
Input
Input
Input
Output
Output
Output
Input A: every 1 ms
Input B: every 1 ms
Input
Input
Input
Output
Output