Digital controller
Hide thumbs Also See for E5AR - MANUAL 2:
Table of Contents

Advertisement

Level
Protect level
RUN level
Adjustment level
Adjustment 2 level
Bank setting level
PID setting level
Approximation setting level
Monitor item level
Input initial setting level
Control initial setting level
Control initial setting 2 level
Alarm setting level
Display adjustment level
Communications setting level
Special function setting level
Expansion control setting level
Calibration level
* To move to the special function setting level, set "Initial setting protect" in the "Protect level" to "0".
l p r t
Description
Settings to prevent accidental key input.
Basic display and settings for operation.
Option settings and control adjustment.
Settings that can be adjusted during operation function control.
SP, PID Set No., and alarm settings of each bank.
P,I,D values of each PID set and limit settings.
Broken-line approximation and straight-line approximation
settings.
Monitor display of set values.
Initial settings related to input.
Initial settings for the output type and control mode.
Initial settings for operation functions.
Alarm type and output settings.
Display adjustment settings.
Communications speed, communication data length, and
other communication settings.
Initialization of settings and PF key settings.
Advanced control settings and position proportional settings.
Calibration by the user.
In following each levels, control is stopped, input initial settings, control
initial setting, control initial settings 2, alarm settings, display
adjustment, communication settings, advanced function settings,
expansion control settings and calibration.
Note that control will stop on all channels if you move to any of these
levels.
Display 3 shows the current level. The characters and the corre-
sponding levels are as follows:
Display 3
l.prt
Protect level
Off *
RUN level
l.adj
Adjustment level
l.ad2
Adjustment 2 level
l.bnk
Bank setting level
l.pid
PID setting level
l.tec
Approximation setting level (Technical)
l.mon
Monitor item level
l.0
Input initial setting level
l.1
Control initial setting level
l.2
Control initial setting 2 level
l.3
Alarm setting level
l.4
Display adjustment level
l.5
Communications setting level
l.adf
Special function setting level
l.exc
Expansion control setting level
l.cal
Calibration
* May appear depending on the selected setting data.
4.1 Setting levels and key operation
Level
Operation
During
operation
When
operation is
stopped
4-3