■ Unit performance specifications

Indication accuracy
Temperature variation
*3
influence
Voltage variation
*3
influence
Control mode
Control period
Proportional band (P)
Integral time (I)
Derivative time (D)
Hysteresis
Manual reset value
Alarm setting range
Input sampling period
Insulation resistance
Voltage resistance
Vibration tolerance
Shock tolerance
Inrush current
Weight
Protective structure
Memory protection
*1
K, T, N at -100°C max.: 2°C 1 digit max..
U and L: 2°C 1 digit max..
B at 400°C max. is not specified.
R and S at 200°C max.: 3°C 1 max..
W: (Larger of 0.3%PV and 3°C) 1 digit max..
*2
U and L: 1°C 1 digit
R and S at 200°C max.: 1.5°C 1 digit.
*3
Ambient temperature: 10 C to 23 C to 55 C
Voltage range: 15% to +10% of rated voltage
*4
EU stands for "Engineering Units" and is regarded as the units after scaling. In the case of a temperature sensor, this is
°C or °F.
Thermocouple input:
( 0.1% of indication value or 1°C, whichever is greater) 1 digit max.
[Not using internal cold contact compensation]
(+0.1% of indication value or 1°C, whichever is smaller) 1 digit max.
Analog input: (0.1% FS) 1 digit max.
Platinum resistance temperature sensor input:
( 0.1% of indication value or 0.5°C, whichever is greater) 1 digit max.
Position proportional potentiometer input:
( 5% FS)
1 digit max.
Thermocouple input (R, S, B, W):
( 1% of PV or 10 C, whichever is greater)
Other thermocouple input:
( 1% of PV or 4 C, whichever is greater)
*K thermocouple at 100 C max: 10 C max.
Platinum resistance thermometer:
( 1% of PV or 2 C, whichever is greater)
Analog input: ( 1%FS) 1 digit max.
Standard control (heating control or cooling control), heating/cooling control
Standard control with remote SP (2-input type only)
Heating/cooling control with remote SP (2-input type only)
Cascade standard control (2-input type only)
Cascade heating/cooling control (2-input type only)
Ratio control (2-input type only)
Position proportional control (control valve control type only)
0.2 to 99.0 seconds (units of 0.1 seconds): During time-divided proportional control output
0.00 to 999.99% FS (units of 0.01% FS)
0.0 to 3999.9 s (units of 0.1 second)
0.0 to 3999.9 s (units of 0.1 second)
0.01 to 99.99% FS (units of 0.01% FS)
0.0 to 100.0% (units of 0.1% FS)
*4
19999 to 99999
(Decimal point position depends on input type and decimal point position setting)
50 ms
20 M
or higher (using 500 V DC insulation resistance tester)
2000 V AC 50/60 Hz 1 min (different pole, charging terminals)
Vibration frequency: 10 to 55 Hz
2
Acceleration: 20 m/s
2
150 m/s
(relay contacts: 100 m/s
3 times each in 3 axes and 6 directions
100 to 240 V AC type: 50 A max.
24 V AC/DC type: 30 A max.
Approx. 450 g (unit only), Fittings: Approx. 60 g,
E5AR
Terminal cover: Approx. 30 g
Approx. 330 g (unit only), Fittings: Approx. 60 g,
E5ER
Terminal cover: Approx. 16 g
Front: IP66, rear case: IP20, terminal plate: IP00
Non-volatile memory (Write count:100,000 times)
1 digit max.
1 digit max.
1 digit max.
2
)
Specifications