Section 6 Communication (CompoWay/F)
Response

■ Bank change

Command
Response
6-22
MRC
SRC
Response code
"30"
"05"
"0000"
Response codes: The above indicates a normal end. For the response
codes, see "6.7 Operation commands (Communication/CompoWay/
F)" (P.6-11).
Instruction
Related
MRC
SRC
code
information
"30"
"05"
"02"
Description
Related
information
Ch
Bank No. selected
"00" to "07"
1
"10" to "17"
2
"20" to "27"
3
"30" to "37"
4
"F0" to "F7"
All
This command is used to change banks (there are 8 banks numbered
0 to 7). An SP, alarm values, and a PID Set No. are stored in each
bank.
This command can be used in both setting area 0 and setting area 1.
• An operation error will result if AT is running in the selected channel.
To use this command, "Write via communication" must be enabled
using the "Write via communication" operation command.
MRC
SRC
Response code
"30"
"05"
"0000"
Response codes: The above indicates a normal end. For the response
codes, see "6.7 Operation commands (Communication/CompoWay/
F)" (P.6-11).
0 to 7
0 to 7
0 to 7
0 to 7
0 to 7